Abstract: The double skin façade (DSF) system is increasingly used for its potential to enhance thermal efficiency
and reduce energy consumption by adapting to external conditions such as solar heat gain and thermal radiation.
While its benefits are well-established in temperate climates, limited and inconclusive evidence exists for its
effectiveness in tropical regions. This study examines DSF performance across two distinct climates using case
studies in Melbourne (temperate) and Singapore (tropical), based on the Köppen-Geiger classification. Three
ventilation modes—natural, mechanical, and mixed are tested, alongside seven shading configurations, which
vary by type, location, and angle within a high-rise building model. Findings show that in temperate climates,
mixed-mode ventilation delivers the highest thermal energy savings, with natural ventilation also offering
benefits under optimal conditions. In tropical climates, ventilation has limited impact due to constant high
temperatures and restricted vent operation. Shading strategies also show different outcomes: in temperate
climates, vertical shading at a 30° angle achieves the greatest energy reduction. In contrast, shading in tropical
conditions has minimal effect on cooling demand, despite effective shading coefficients. Overall, DSFs perform
well in temperate climates but face significant limitations in tropical environments. Future research should focus
on internal heat gains, vent operation, and airflow dynamics to better optimise DSF systems for hot and humid
climates.

Keywords: Double Skin Façade, Energy Simulation, Ventilation, Shading