Abstract: This paper presents a systematic calibration process for Building Performance Simulation (BPS) models
using measured data. Assessing window performance and passive cooling effectiveness in dense urban
residential settings requires greater precision compared to conventional calibration, which often focuses
primarily on energy use. Models must reflect detailed contextual factors that influence dynamic and diverse
occupant behaviour. A literature review indicated that occupant behaviour and site-specific weather data during
the measurement period are major contributors to performance gaps. Based on these insights, a five-stage
calibration process was developed: (1) examining measured data, (2) selecting accurate weather data, (3)
running simulations, (4) calculating discrepancies, and (5) identifying optimal models. An in-depth analysis of
two Auckland apartment units revealed that increased relative humidity and carbon dioxide levels were strongly
associated with higher indoor temperatures, reflecting distinct behavioural patterns under both typical and
atypical scenarios. Integrating these patterns and refined weather data into iterative evaluations of window and
ventilation configurations reduced the discrepancy between measured and simulated results by up to 42% in
the final consolidated annual model. The final model was derived from a combination of the optimal models
representing annual conditions, along with atypical summer and winter scenarios. The findings highlight the
importance of high-resolution, context-specific input data in producing realistic and reliable BPS outcomes. The
proposed calibration method offers a replicable framework for improving simulation accuracy in residential
studies, particularly those addressing passive design strategies and occupant behaviour in complex urban
environments, even when detailed survey data on occupant activities are unavailable.
Keywords: Building performance simulation; EnergyPlus; passive cooling; window-opening behaviour.