Extract
Abstract: Section J of the National Construction Code (NCC) of Australia (Volume 1) sets requirements for energy efficiency for non-residential buildings. This paper reports the results of analyses undertaken to revise the glazing solar admittance requirements for the next update of the NCC. In these analyses, a series of daylighting simulations calculating the spatial Daylight Autonomy (sDA) for a grid of window wall ratio and visual light transmission combinations was used to derive minimum visual solar admittance figures (WWR*VLT) compatible with a nominated minimum daylighting performance. A database of available glazing products was then used to convert these visual figures to equivalent thermal solar admittances (WWR*SHGC). Dynamic thermal simulation was then used to test whether these solar admittances coincide with minimum energy consumption. It was found that this is true in all climate zones other than climate zone 8 (Alpine). Based on this, the new requirements can be expressed as a simple table of solar admittance versus climate zone. The results lead to a recommendation to tighten the deemed-to-satisfy solar admittance requirements for commercial buildings in the next edition of the NCC.
Keywords: National Construction Code; Glazing; Solar Admittance; Daylighting.