Acoustics performance of a multi-functional learning space of heritage significance

  • YEAR
    2025
  • AUTHORS
    Kusuma, Kenny Indrajaya
    Rajagopalan, Priyadarsini
  • CATEGORIES
    2025 Conference Papers

Extract

https://doi.org/10.65388/EZZK4439

Abstract: This study investigates the acoustic performance of a heritage-listed space in a university building in Melbourne, currently used for training and workshop purposes. The space with a volume of 1563 m³ approximately, was evaluated based on reverberation time (T20 and EDT), background noise level, and speech intelligibility index (STI). The existing conditions were then simulated using I-SIMPA. Overall, the initial measurements revealed poor acoustic conditions with T20, EDT, and STI with values of 1.96 s, 2.00 s, and 0.46 respectively. Background noise levels were within acceptable limits, ranging from 41.3 – 42.1 dBA. Several acoustic treatments were introduced in the simulation, improving T20 and STI to 1.08 s and 0.548 respectively. Environmental and economic assessments were also conducted based on embodied carbon and costs of the treatments. The best performing treatments was found to be installation of acoustic panels on walls, improving T20 to 1.41 s, and STI to 0.529. Further analyses were conducted to see the effect of reverberation
and signal to noise ratio on STI. Installing acoustic panels all over the wall and increasing the signal by 6 dB improved the STI value to 0.632. These findings demonstrate that it is possible to reduce the reverberation time to the recommended duration through targeted acoustic treatments. However, additional strategies are required to further enhance the speech intelligibility in the room.

Keywords: Acoustic treatments; reverberation; STI; heritage buildings.

PDF

Download

RIS

Download
To top